Power Supply Unit Selection for Each Shelf
The PBX needs a power supply unit (PSU) suitable for its configuration. For each shelf, calculate the load
figure from the type and number of items of equipment to be connected, and then determine the type of PSU
that will be required.
Note
Regardless of the total load figure, if a shelf contains an ECSLC24 card, the PSU-L must be installed.
Load Figure Calculation
Equipment Type
Load Figure
PT KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
KX-T7560/KX-T7565 DPT 1
Other DPT/Other DSS console 4
APT 4
IP-PT 0
SIP Extension 0
Extension Card
*1
DHLC8 8
SLC8 8
ESLC16/CSLC16/EMSLC16 16
ECSLC24 24
CS (1 unit) 4
High-density CS (1 unit) 8
IP-CS (1 unit) 0
VPS (1 port) 1
*1
Only the extension cards that can support SLTs count for the load figures.
40 Installation Manual Document Version 2009-12