Model No. KX-TDE600Pure IP-PBXInstallation ManualSD Logo isa trademark.Document Version: 2009-12Thank you for purchasing a Panasonic Pure IP-PBX.Pl
1. Information stored on the SD Memory CardPhonebook data, user IDs, system settings data, passwords (User/Administrator/Installer), PersonalIdentific
2. Check that the shelves are standing exactly vertically. If the shelves are leaning slightly to one side, movethe base stands to adjust the position
Installing Expansion Shelves 2 and 3Repeat the procedure in "Installing the Basic Shelf and Expansion Shelf 1" for Expansion Shelves 2 and 3
Connecting ShelvesFor the 4-shelf system, you need to install an optional BUS-M card and BUS-ME cards in the Basic Shelf. Toconnect the shelves, plug
3. Push the release lever in the direction of the arrow so that the BUS-M card engages securely with theconnector on the back board.Release LeverBack
5. Plug each Bus Cable into the corresponding port of the BUS-M card in the Basic Shelf. Then, plug theother end into the BUS-S card in each Expansion
6. Attach the noise shield wires of each Bus Cable to the Basic Shelf and each Expansion Shelf with thescrews of the BUS-M card.NoteWhen attaching or
3.2.8 Wall Mounting (KX-TDE600/KX-TDE620)Mounting ShelvesWARNING• Make sure that the wall that the shelf will be attached to is strong enough to supp
1. Install 4 anchor plugs in the wall, using the metal bracket as a template. Fix the metal bracket with 4 screws(A).30 mm(1-3/16 in)8 mm(5/16 in)Anch
2. Hook the shelf onto the metal bracket, making sure that the shelf slides down and onto the hooked partsof the metal bracket. Use 2 screws (B) to fi
3.2.9 Installing/Replacing the Power Supply UnitFunctionPSU Type Lower/Upper Input Voltage Range Current Input FrequencyPSU-MLower: 100 V AC to 130 V
PrecautionWARNINGDO NOT REMOVESD MEMORY CARDWHILE POWER ISSUPPLIED TO THE PBXDoing so may cause the PBX to fail to start when you try to restart the s
The following procedures are for installing or replacing a PSU only. Do not replace or remove the PSUfor any other purpose.Installing the Power Supply
3. Turn the 4 screws clockwise, in the order indicated by the numbers 1 to 4, to fix the PSU.1324ScrewsReplacing the Power Supply Unit1. Unplug the AC
3. Pull the release lever in the direction of the arrow to disconnect the PSU from the back board.Release LeverBack Board4. Replace the PSU.Current PS
3.2.10 Frame Ground Connection1. Loosen the screw.2. Insert a grounding wire (user-supplied).3. Tighten the screw.4. Connect the grounding wire to gr
3.2.11 Installing/Removing the Optional Service CardsCAUTION• To protect the back board from static electricity, do not touch parts on the back board
3. Turn the 2 screws clockwise to fix the card in place.ScrewsNoteMake sure the screws are tightened to ground the card securely.Document Version 200
Covering the Blank SlotsBe sure to cover each slot in which no optional service card is installed by using a Blank Slot Cover.CAUTIONFailure to instal
Removing the Optional Service Cards1. Turn the 2 screws counterclockwise to loosen them.Screws2. Pull the release lever in the direction of the arrow
3.2.12 Cable HandlingNoteFor safety reasons, do not stretch, bend, or pinch the AC power cord.Cable Handling for Each ShelfWhen cables are connected
Cable Handling for Connected ShelvesWhen running connected cables towards the back of the shelves, make sure not to block the opening of eachFan Guard
Password SecurityCAUTIONTo the Administrator or Installer regarding the system password1. Please provide all system passwords to the customer.2. To av
3.2.13 Types of ConnectorsConnector Type Pin Number Used forRJ11(Twisted pair cable)14• DHLC8 (KX-TDA0170)• SLC8 (KX-TDA0173)• CSLC16 (KX-TDA0177)• E
Connector Type Pin Number Used forRS-232C(Shielded cable)9 56 1• Basic Shelf (KX-TDE600)Mini Plug24• IPCEMPRDocument Version 2009-12 In
3.2.14 Attaching a Ferrite CoreA ferrite core must be attached when:• an RJ45 connector is connected to IPCEMPR, IP-GW16 or IP-EXT16 cards, or• an Am
Attaching to an Amphenol ConnectorFor Extension CardsPass the cable through the ferrite core, then close the case of the ferrite core. Attach the ferr
3.2.15 Fastening Amphenol ConnectorAn Amphenol 57JE-type connector is used on some of the optional service cards.To connect an Amphenol connector, us
Amphenol Connector Pin Assignment ChartBelow is an Amphenol connector pin assignment chart for all optional service cards that use the Amphenolconnect
3.2.16 Surge Protector InstallationCAUTIONPerforming surge protection is essential. Make sure to follow the instructions in this section.OverviewA ma
Outside Installation(Main Building)CO LineCO LineExtn.Extn.Extn.: Extension LineGroundExtn.Surge ProtectorSurgeProtectorPBXExtn.SLTPTPT-interface CSCS
1. Connect the grounding rod to the surge protector using a grounding wire with a cross-sectional area of atleast 1.3 mm2.2. Bury the grounding rod ne
IntroductionThis Installation Manual is designed to serve as an overall technical reference for the Panasonic Pure IP-PBX,KX-TDE600. It provides instr
F.C.C. REQUIREMENTS AND RELEVANTINFORMATION1. Notification to the Telephone CompanyThis equipment complies with Part 68 of the FCC rules and the requi
interference in a residential installation. This equipment generates, uses, and can radiate radio frequencyenergy and, if not installed and used in ac
Table of Contents1 System Outline ...191.1 System Construction ...
3.7.2 CID8 Card (KX-TDA0193) ...1423.7.3 T1 Card (KX-TDA0187)
6 Appendix ...2216.1 Revision History ...
Section 1System OutlineThis section provides general information on the PBX,including the system capacity and specifications.Document Version 2009-1
System ComponentsSystem Components TableCategory Model No. DescriptionBasic Shelf KX-TDE600 Basic ShelfMain Processing Card Main Processing Card (IPCE
1.1 System Construction1.1.1 Basic SystemBasic ShelfThe Basic Shelf contains an IPCEMPR card for controlling the PBX. To use the basic system, insta
1.1.2 Expanded SystemExpansion ShelfEach Expansion Shelf contains a BUS-S card for connecting to the Basic Shelf. To use Expansion Shelf,connect it t
2-shelf SystemExpanded system (Basic Shelf + 1 Expansion Shelf). Expansion Shelf 1 is mounted on the Basic Shelf.CAUTIONIf you are installing a 2-shel
3-shelf System (Tower Type)Expanded system (Basic Shelf + 2 Expansion Shelves). Expansion Shelves 1 and 2 are mounted on the BasicShelf. A Mounting Ki
4-shelf System (Tower Type)Fully expanded system (Basic Shelf + 3 Expansion Shelves). Expansion Shelves 1 to 3 are mounted on theBasic Shelf. A Mounti
4-shelf System (Side-by-side Type)When vertical space is limited, it is possible to install a fully expanded system (Basic Shelf + Expansion Shelf1, a
1.1.3 System Connection DiagramDoorphone & Door OpenerBGM/Music On Hold (MOH)Pager/SpeakerRemote PCPCPrinterCO (Telephone Company) LinesAnalog/PR
CSIF4(KX-TDA0143)CSIF8(KX-TDA0144)PSU-M/L(KX-TDA0104/KX-TDA0103)EMSLC16(KX-TDA6175)EXT-CID(KX-TDA0168)ESLC16(KX-TDA6174)SLC8(KX-TDA0173)DSP16(KX-TDE01
1.2 Optional Equipment1.2.1 Optional EquipmentModel No. Model Name DescriptionKX-TDE0105 Memory Expansion Card(IPCMEC)Memory expansion card to incre
Model No. Model Name DescriptionKX-TDA0177 16-Port Single Line TelephoneExtension Card with Caller ID(CSLC16)16-port extension card for SLTs with Call
Category Model No. DescriptionKX-NCS4704 4-Channel SIP Extension Activation Key (4 SIP Extension)KX-NCS4708 8-Channel SIP Extension Activation Key (8
Model No. Model Name DescriptionKX-TDA6175 16-Port Single Line TelephoneExtension with Message LampCard (EMSLC16)16-port extension card for SLTs with
1.3 Specifications1.3.1 General DescriptionControl Bus Original bus (16-bit, 8 MHz, 10 megabytes per second)Communication Bus H.100 bus conformity (
PT-interface CS 1-pair wire (D1, D2)PT-interface CS (High-density) 4-pair wire (D1, D2)DSS Console and Add-on KeyModule1-pair wire (D1, D2)Dimension B
1.3.2 CharacteristicsTerminal Equipment Loop Limit• PT: KX-DT300/KX-T7600 series DPT: 90 W; all other DPTs/APTs:40 W• SLT: 600 W including set• Doorp
1.3.3 System CapacityType and Maximum Number of SlotsThe PBX supports the following type and number of slots.Slot TypeMaximum NumberBasic System2-she
Virtual Slots of the IPCEMPR CardIPCEMPR CardVirtual SlotsVirtual CO Line SlotsVirtualExtension SlotsMaximum Optional Service CardsThe following numbe
Cards Installed in Free Slots or Virtual Slots*1 *1*3BasicSystem112214 4044103054010 40V-IPGW16ELCOT16T1PRI23IP-GW4EIP-GW16V-IPEXT32V-IPCS4V-SIPEXT32D
Cards Mounted on Other Optional Service CardsCard TypeMaximum NumberMounted onBasic System2-shelfSystem3-shelfSystem4-shelfSystemDSP161IPCEMPRCardDSP6
Maximum CO Lines and ExtensionsThe PBX supports the following number of CO lines and extensions.TypeBasicSystem2-shelfSystem3-shelfSystem4-shelfSystem
Maximum Terminal EquipmentThe following number of items of terminal equipment can be supported by the PBX.Terminal Equipment Type Basic System2-shelfS
Category Model No. DescriptionKX-TDA0170 8-Port Digital Hybrid Extension Card (DHLC8)KX-TDA0171 8-Port Digital Extension Card (DLC8)KX-TDA0172 16-Port
Note for KX-NT265 IP-PT usersThe supported card varies depending on the software version of your KX-NT265 IP-PT. To confirm the version,follow the pro
PSU CapacityEach PSU supports a different load figure.PSU Type Maximum Load FigurePSU-M 128PSU-L 512If the total load figure is greater than 128, you
42 Installation Manual Document Version 2009-12 1.3.3 System Capacity
Section 2Activation Key InstallationThis section describes information on activation keys,including how to obtain an activation key and install it in
2.1 Information about the Activation Keys2.1.1 Activation KeysTo use IP CO lines and IP telephones on a private IP network using the IPCEMPR card or
Activation Key Type DescriptionMaximumNumberSupported IP CO lines/IP Telephones/CAUsersCA Basic 128usersAllows the use of CA Basic for 128users.1 128
Activation Keys for IP CO LinesModel No. Activation Key TypeMaximum Number/Supported IP CO Lineswith DSP16 with DSP64KX-NCS4102 2 IP Trunk 3060 IP CO
Model No. Activation Key Type Maximum Number Supported CA UsersKX-NCS2205 CA Pro 5users 25 125 usersKX-NCS2210 CA Pro 10users 12 120 usersKX-NCS2240 C
2.1.2 Activation Key Code and Key Management SystemTo obtain additional activation keys, you need to purchase the appropriate activation key codes an
2.1.3 Activation Key FileThe corresponding number of IP CO lines and IP telephones or enhanced features can be activated by installingthe downloaded
Category Model No. DescriptionProprietary Equipment KX-A258 Blank Slot CoverKX-T30865 DoorphoneKX-T7765KX-T7775*1Note that the types of activation key
50 Installation Manual Document Version 2009-12 2.1.3 Activation Key File
Section 3InstallationThis section describes the procedures to install thePBX. Detailed instructions for planning the installationsite, installing the
3.1 Before Installation3.1.1 Before InstallationPlease read the following notes concerning installation and connection before installing the PBX and
• Do not stack up the optional service cards.Wiring PrecautionsBe sure to follow these instructions when wiring the unit:WARNING• Do not run unshielde
3.2 Installation of the PBX3.2.1 UnpackingSupplied Items for the Basic Shelf (KX-TDE600)Unpack the box and check the items below:Main Unit 1Ferrite
Supplied Items for an Expansion Shelf (KX-TDE620)Unpack the box and check the items below:Main Unit 1Metal Bracket 1Anchor Plug 4Fan Guard 2Screw A 4S
3.2.2 Names and LocationsInside ViewBasic Shelf (KX-TDE600) Expansion Shelf (KX-TDE620)ABFCABGEJKHEDIA. RUN IndicatorB. ALARM IndicatorC. MNT PortD.
3.2.3 Opening/Closing the Front CoverOpening the Front Cover1. Insert a flathead screwdriver into the opening (on the left of the screw cover) and un
Closing the Front Cover1. Hook the front cover onto the shelf (line up the protrusions on the cover with the receptacles on the shelf).Then slide the
3.2.4 Attaching Fan GuardsAttaching Fan GuardsFan Guards (supplied with the shelf) must be attached using the screws (C) when:• installing a multiple
• Single line telephonesIncompatible Panasonic Proprietary TelephonesThe PBX does not support the following telephones:• KX-T30800 series proprietary
3.2.5 Installation of Basic System or 2-shelf System (FloorStanding)The PBX can be expanded to a 2-shelf system by mounting an Expansion Shelf on the
Installing the Basic ShelfFor the basic system, install the metal bracket (supplied with the Basic Shelf) on the floor first. Then, attachthe Basic Sh
3. Secure the Basic Shelf to the metal bracket with 2 screws (B).Screw (B)Installation of the basic system is complete. If you are installing a 2-shel
2. Fix the metal bracket to the Basic Shelf with 4 screws (B).TOPScrew (B)Metal Bracket3. Lift Expansion Shelf 1, attach it to the metal bracket on th
4. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B).Screw (B)Shelf installation is complete. Next, it is necessary to connect the shelv
Connecting ShelvesFor the 2-shelf system, you need to install an optional BUS-M card in the Basic Shelf. To connect the shelves,plug the Bus Cable (su
3. Turn the 2 screws clockwise to fix the BUS-M card in place.Screws4. Plug the Bus Cable into the bottom port of the BUS-M card in the Basic Shelf. T
5. Attach the noise shield wires of the Bus Cable to the Basic Shelf and Expansion Shelf 1 with the screwsof the BUS-M card.NoteWhen attaching or remo
3.2.6 Installation of 3- or 4-shelf System (Tower Type)The PBX can be expanded to a 3- or 4-shelf system by mounting Expansion Shelves on the Basic S
WARNINGBe careful not to drop any components. Dropping components may damage them or cause aninjury.CAUTION• Do not block the openings of the shelf. A
Important Safety InstructionsWhen using your telephone equipment, basic safety precautions should always be followed to reduce the riskof fire, electr
NoteIf necessary, it is possible to reverse the direction of the base stands as shown below:2. Place the metal bracket on the base stands.Metal Bracke
3. Attach the metal bracket to the base stands with 4 screws (B).Screw (B)4. Make 4 holes for anchor plugs on the floor, using the measurements indica
5. Install 4 anchor plugs in the holes on the floor.Then, fasten the base stands to the floor loosely with 4 screws (A). (This makes it easy to adjust
7. Lift the Basic Shelf, attach it to the metal bracket, and slide it backwards until it locks.FRONT12FRONT12TOPTOPMetal Bracket8. Secure the Basic Sh
Mounting Expansion Shelves 1 and 2For the 3- or 4-shelf system, attach the metal bracket (supplied with the Expansion Shelf) to the Basic Shelffirst.
3. Lift Expansion Shelf 1, attach it to the metal bracket on the Basic Shelf, and slide it backwards until it locks.12Metal Bracket4. Secure Expansion
Fixing to the Wall1. Attach the metal bracket to the wall brackets.Wall Bracket (Left) Wall Bracket (Right)Metal Bracket2. Fix the metal bracket to Ex
3. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wallwith 4 screws (A).Notice• Drive mountin
4. Check that the shelves are standing exactly vertically. If the shelves are leaning slightly to one side, movethe base stands to adjust the position
Expansion Shelf 21. Lift Expansion Shelf 2, attach it to the metal bracket fixed on Expansion Shelf 1, and slide it backwardsuntil it locks.12Metal Br
Important InformationSAVE THESE INSTRUCTIONSWARNINGSAFETY REQUIREMENTSFor All Telephone Equipment• Do not install the product in any other way than de
Mounting Expansion Shelf 3For the 4-shelf system, attach the metal bracket (supplied with Expansion Shelf 3) to Expansion Shelf 2 first.Then, attach t
3. Remove the 4 tabs on the top cover of Expansion Shelf 3, by using a flathead screwdriver, as shown below.Expansion Shelf 34. Fasten the wall bracke
5. Lift Expansion Shelf 3, attach it to the metal bracket fixed on Expansion Shelf 2, and slide it backwardsuntil it locks.12Metal Bracket82 Installat
6. Secure Expansion Shelf 3 to the metal bracket with 2 screws (B).Screw (B)Document Version 2009-12 Installation Manual 833.2.6 Installation of 3-
Fixing to the Wall1. Install 4 anchor plugs in the wall, using the wall brackets as a template. Fix the wall brackets to the wallwith 4 screws (A).Not
2. Check that the shelves are standing exactly vertically. If the upper shelves are leaning slightly to one side,move Expansion Shelf 3 to adjust the
Connecting ShelvesFor a 3- or 4-shelf system, you need to install an optional BUS-M card and BUS-ME card(s) in the Basic Shelf.To connect the shelves,
3. Push the release lever in the direction of the arrow so that the BUS-M card engages securely with theconnector on the back board.Release LeverBack
5. Plug each Bus Cable into the corresponding port of the BUS-M card in the Basic Shelf. Then, plug theother end into the BUS-S card in each Expansion
6. Attach the noise shield wires of each Bus Cable to the Basic Shelf and each Expansion Shelf with thescrews of the BUS-M card.NoteWhen attaching or
• Unplug all installed shelves of the system from the AC outlet if it emits smoke, an abnormal smell or makesunusual noise. These conditions can cause
3.2.7 Installation of 4-shelf System (Side-by-side Type)When vertical space is limited, it is possible to install shelves side-by-side. Installing th
Installing the Basic Shelf and Expansion Shelf 1To install the Basic Shelf, attach the metal bracket (supplied with the Basic Shelf) to the base stand
2. Place the metal bracket on the base stands.Metal Bracket3. Attach the metal bracket to the base stands with 4 screws (B).Screw (B)92 Installation M
4. Make 4 holes for anchor plugs on the floor, using the measurements indicated here.510 mm(20-1/16 in)*FloorWall287 mm(11-5/16 in)95 mm(3-3/4 in)382
5. Install 4 anchor plugs in the holes on the floor.Then, fasten the base stands to the floor with 4 screws (A).Anchor PlugHammer30 mm(1-3/16 in)8 mm(
7. Lift the Basic Shelf, attach it to the metal bracket, and slide it backwards until it locks.FRONT12FRONT12TOPTOPMetal Bracket8. Secure the Basic Sh
Expansion Shelf 11. Fix the metal bracket to the Basic Shelf with 4 screws (B).TOPScrew (B)Metal Bracket2. Remove the 4 tabs on the top cover of Expan
3. Fasten the wall brackets loosely to Expansion Shelf 1 with 4 screws (D). (This makes it easy to adjust theposition of the shelves later.)Screw (D)W
5. Secure Expansion Shelf 1 to the metal bracket with 2 screws (B).Screw (B)Fixing to the Wall1. Install 4 anchor plugs in the wall, using the wall br
• When installing anchor plugs in the wall, be careful not to damage or dirty the shelves.Screw (A)WasherWallWall Bracket (Left) Wall Bracket (Right)A